Thiết bị kiểm tra di động cho bộ sạc AC EV TD1330


TD1330 is a portable instrument dedicated to on-site inspection of EV AC charging spot, with three-phase AC voltage measurements up to 300 V, three-phase AC current measurements up to 78 A, and AC electrical energy measurement available in class 0.05 / 0.1. The instrument can be combined with TK4720 AC adjustable resistive load to complete the metrology characteristics test and interoperability test of AC charging spot.

• AC harmonic measurement: Harmonics order of 2 to 64 can be detected.

• Power waveform display: Real-time charging curve U(t), I(t), P(t), E(t) display and record, etc.

• Ambient temperature measurement: Built-in temperature sensor for measuring the ambient temperature of the site to correct the working error.

• Clock verification function: Built-in GPS clock module, real-time clock display, and correct the Beijing time of the charging spot.

• Integration: Built-in measurement module, charge control guidance circuit, waveform acquisition and other modules, can complete all interoperability test items of AC charging spots.

• Built-in vehicle control guidance circuit: AC charging spot interoperability test can be completed, built-in L1, L2, L3, N, PE, CP, CC circuit on-off switch and CP ground short circuit switch, can realize the vehicle AC charging interface circuit fault simulation function. Built-in vehicle-side R2 resistance, R3 resistance simulation equivalent resistance simulation function, R2 resistance has adjustment range of 500 Ω ~ 6800 Ω, with resistance value online continuously adjustable with adjustment fineness of 1 Ω; R3 equivalent resistance has nominal value of 500Ω ~ 13000Ω, with resistance value online continuously adjustable with adjustment fineness of 1 Ω. Each contact point has an on-off switch, which can simulate the on-off state of the contact point.

• Waveform acquisition: Built-in 4-channel high-speed waveform acquisition module to ensure long-term operation and zero data loss.

• PWM signal measurement: Measure the frequency and duty factor of the PWM signal on the CP line in the control guidance circuit and display it in real time.

• High reliability: No switches, relays and other mechanical contacts in the current loop, can be overloaded at 2 times the rated current for 5 s.

• Calibration and verification: With dedicated calibration terminals, the device can be calibrated or verified by two methods, and the TK4965 AC charging electrical energy calibration adapter is optional.

• High-definition LCD touch color screen.

• Ethernet, WIFI, USB, CAN-BUS interface and host computer software.

• Support input of commercial power, built-in lithium battery and EV charger power supply.

• Equipped with portable instrument box, high seismic and electrical protection level.

Three-phase ACV measurement

Range

Resolution

Accuracy

( ± ppm of reading + ppm of range) [1]

Temp. Coefficient, ± ppm*RD /°C

@-25~55

Class 0.1

Class 0.05

Class 0.1

Class 0.05

240 V

0.1 mV

400 + 100

200 + 50

30

20

Note [1] : (ppm = parts per million) (e.g., 10ppm = 0.001%).

• Range: Manual/auto shift

• Measurement range: 30 V ~ 300 V

• Harmonic measurement uncertainty (k = 2): 0.05% * RG, RMS


Three-phase ACI measurement

Range

Resolution

Accuracy

( ± ppm of reading + ppm of range)

Temp. Coefficient, ± ppm*RD /°C

@-25~55

Class 0.1

Class 0.05

Class 0.1

Class 0.05

100 mA

0.1 μA

400 + 100

200 + 50

50

20

200 mA

0.1 μA

400 + 100

200 + 50

50

20

500 mA

0.1 μA

400 + 100

200 + 50

50

20

1 A

1 μA

400 + 100

200 + 50

50

20

2 A

1 μA

400 + 100

200 + 50

50

20

5 A

1 μA

400 + 100

200 + 50

30

20

10 A

10 μA

400 + 100

200 + 50

30

20

30 A

10 μA

400 + 100

200 + 50

30

20

60 A

10 μA

400 + 100

200 + 50

30

20

• Range: Manual/auto shift

• Measurement range: 10 mA ~ 78 A

• Harmonic measurement uncertainty (k = 2): 0.05% * RG, RMS


Frequency and phase

• Frequency range: 45.000 Hz to 65.000 Hz.

Resolution: 0.001 Hz, uncertainty (k=2): 0.01 Hz.

• Phase range: 0.000°~359.999°

Resolution: 0.001°, uncertainty (k=2): 0.025°


P/E Energy Measurement

Electrical energy under test


Accuracy

Class 0.1

Class 0.05

Active power/electrical energy

|cosΦ| ≥0.5;

0.1%*RD

0.05%*RD

• Measuring range of power/energy: Combination of AC voltage and AC current range;

• Power factor measurement range: -1.000000…0.000000…1.000000

• Standard electrical energy pulse output: maximum frequency is 60 kHz

Supports active and passive pulses, load capacity: greater than 20 mA

• Standard electrical energy pulse input: maximum frequency is 100 kHz, level: 0 ~ 5V


Temperature Clock

DC power / electrical energy

Range

-30~60

Accuracy

0.3

Clock function

Timing mode

GPS clock timing

Accuracy

1s/d


5. General Specifications

Power supply mode

EV charger, built-in lithium battery, 220V commercial power

Power supply

AC ( 220 ± 22 ) V, ( 50 ± 2 ) Hz

Max. Power

80 VA

Communication interface

USB, LAN, WIFI

Temperature performance

Operating temperature: -25°C~55°C

Storage temperature: -30°C~70°C

Humidity Performance

Operating humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C

Storage humidity: <80% R·H, non-condensing。

Altitude

< 3000 m

Weight

About 13 kg

Dimensions

390 mm(W)× 400 mm(D)× 260 mm(H)