TD1090


• Nominal input current: 1 kA or 2 kA

• Nominal output voltage: 1 V

• Measurement frequency: 40 Hz ~ 400 Hz

• Accuracy: Class 0.005 or Class 0.01

• Through-core measurement

• The primary input is galvanically isolated from the secondary output

TD1090 through-center AC I/V converter uses the through-core measurement method to convert AC high current into small voltage, realizing accurate measurement of AC high current, which can be applied to calibrating AC high current sources, current transformers and other devices.

4. Specifications

Nominal input current

A

Nominal output voltage

In

Conversion scale

K

frequency

Hz

Measurement uncertainty (k=2) @ 50 Hz

Class 0.005

Class 0.01

1000

1

1000:1

40≤F≤400

50 ppm

100 ppm

2000

1

2000:1

40≤F≤400

50 ppm

100 ppm

• Measuring range: (10% ~ 110%)*FS

 

5. General Specifications

Working environment

Temperature: 5°C~ 40°C

Humidity: 20% R·H ~ 85%R·H, no condensation.

Others: No electromagnetic field interference.

Storage environment

Temperature:-2 0°C ~ 70°C

Humidity: <95% R·H, no condensation.

Altitude

<3000 m

Size

170 mm (W) × 200 mm (D) × 100 mm (H) × Ø50 mm (d)

Quality

Approx 4 kg