TD1050 Calibration Device for Clamp Meter


• Accuracy: Class 0.05

• DC current: 10 m~ 1050 A(2100 A is optional)

• AC current output: 10 mA 1020 A(2050 A is optional)

• DC voltage output(optional): 20 mV ~ 1100 V

• AC voltage output(optional): 1 V ~ 825 V

• Frequency: 40 H~ 400 Hz

• DC resistance output(optional): 10 Ω ~ 11 MΩ

• Two thickness copper rings

• AC/DC power output(optional)

TD105is a calibration apparatus for multifunctional clamp meters, which integrates functions such as AC/DC high current standard source, AC/DC voltage standard source, and resistance standard source, and also has AC/DC power output function, which can meet the calibration needs of multifunctional clamp meters with different accuracy levels.

Power supply

AC (380 ± 38)V,( 50 ± 2 ) Hz

Max Power Consumption

16 kVA @ 1000 A Model,32 kVA @ 2000 A Model

Operating Condition

0°C~40°C,(20%~85%) R·H,non-condensing

Storage Condition

-20°C~70°C,(10%~95%) R·H,non-condensing

Standard Interfaces

RS232×1

Dimensions





Range


Width(W)


Depth(D)


Height(H)


Diameter of

the copper ring

Ring 1(Ø1)

Ring 2(Ø2)

1000 A

740 mm

1723 mm

1467 mm

10 mm

19 mm

2000 A

1480 mm

1723 mm

1467 mm

10 mm

27 mm

 DC Current

Copper Ring

Range

Resolution

Output Range

Max Load

Ring 1







100 mA

1 μA

10.000 mA ~ 110.000 mA

8 V

300 mA

1 μA

30.000 mA ~ 330.000 mA

8 V

1 A

10 μA

0.10000 A ~ 1.10000 A

8 V

3 A

10 μA

0.30000 A ~ 3.30000 A

8 V

10 A

100 μA

1.0000 A ~ 11.0000 A

8 V

30 A

100 μA

3.0000 A ~ 33.0000 A

8 V

100 A

1 mA

10.000 A ~ 110.000 A

8 V

Ring 2




250 A

1 mA

20.000 A ~ 275.000 A

8 V

500 A

1 mA

50.000 A ~ 550.000 A

8 V

1000 A

10 mA

100.00 A ~ 1050.00 A

8 V

2000 A [1]

10 mA

200.00 A ~ 2100.00 A

8 V

Note[1]2000 A is Optional

Range

Stability (± %/min)

Accuracy

± (ppm*RD+ppm*RG) [2]

Ripple Factor (%)

100 mA

0.01

300 + 100

<0.5

300 mA

0.01

300 + 100

< 0.5

1 A

0.01

300 + 100

< 0.5

3 A

0.01

300 + 100

< 0.5

10 A

0.01

300 + 100

< 0.5

30 A

0.01

300 + 100

< 0.5

100 A

0.01

300 + 100

< 0.5

250 A

0.01

300 + 100

< 0.5

500 A

0.01

300 + 100

< 0.5

1000 A

0.01

300 + 100

< 0.5

2000 A

0.01

300 + 100

< 0.5

Note[2]RD=Reading,RG=Range, unless otherwise noted

• Output range: 10 mA ~ 1050 A\2100 A

• Manual or automatic range switch.

• Adjustment fineness0.002%*RG

• 6 digits decimal display

• Protectionsopen-circuit protection, overload protection, over-heat protection

☆ Calibrate Clamp Meter by Single-turn Method
☆ Calibrate Clamp Power Meters(optional)
☆Calibrate Multi-function Clamp Meters(optional)