TD1000 Calibration Device for Clamp Meters


• Accuracy: Class 0.05, Class 0.1 available

• AC current output: 20 mA ~ 1100 A

• AC voltage output: 1 V ~ 825 V

• DC current output(optional): 20 mA ~ 22A

• DC voltage output(optional): 20 mV ~ 1100V

• DC resistance output: 10 Ω ~ 11 MΩ

• Two thickness copper rings

• Remote adjustment(optional)

TD1000 is a calibration apparatus for multifunctional clamp meters, which integrates functions such as AC/DC high current standard source, AC/DC voltage standard source, and resistance standard source, which can meet the calibration needs of multifunctional clamp meters with different accuracy levels.

8. General Specifications

Power supply

AC (220 ± 22) V,(50 ± 2) Hz

Max power consumption

2.5 kVA

Operating condition

0°C ~ 40°C,(20% ~ 85%) R·H,non-condensing

Storage condition

-20°C ~ 70°C,(10% ~ 95%) R·H,non-condensing

Standard interfaces

RS 232

Dimensions


2310 mm (W)×750 mm (D)×1280 mm (H)

6.1 AC Current

Range

Resolution

Output Range

Frequency

Max Compliance Voltage (rms)

200 mA

1 μA

10.000 mA ~ 210.000 mA

45 Hz ~ 65 Hz

50 V

1 A

10 μA

0.10000 A ~ 1.10000 A

45 Hz ~ 65 Hz

15 V

5 A

10 μA

0.50000 A ~ 5.50000 A

45 Hz ~ 65 Hz

8 V

20 A

100 μA

2.0000 A ~ 22.0000 A

45 Hz ~ 65 Hz

2 V

50 A

100 μA

5.0000 A ~ 55.0000 A

45 Hz ~ 65 Hz

1 V

100 A

1 mA

10.000 A ~ 110.000 A

45 Hz ~ 65 Hz

0.7 V

250 A

1 mA

25.000 A ~ 275.000 A

45 Hz ~ 65 Hz

0.7 V

500 A

1 mA

50.000 A ~ 550.000 A

45 Hz ~ 65 Hz

0.7 V

1000 A

10 mA

100.00 A ~ 1100.00 A

45 Hz ~ 65 Hz

0.7 V


Range


Stability

(± %/min)

Accuracy

± (ppm*RD+ppm*RG)

Distortion (%)


Class 0.05

Class 0.1

Class 0.05

Class 0.1

200 mA

0.01

0.02

250 + 150

600 + 400

<0.5

1 A

0.01

0.02

250 + 150

600 + 400

< 0.5

5 A

0.01

0.02

250 + 150

600 + 400

< 0.5

20 A

0.01

0.02

250 + 150

600 + 400

< 0.5

50 A

0.01

0.02

250 + 150

600 + 400

< 0.5

100 A

0.01

0.02

250 + 150

600 + 400

< 0.5

250 A

0.01

0.02

250 + 150

600 + 400

< 0.5

500 A

0.01

0.02

250 + 150

600 + 400

< 0.5

1000 A

0.01

0.02

250 + 150

600 + 400

< 0.5

Note[1]RD=Reading,RG=Range, unless otherwise noted

• Output range: 20 mA 1100 A

• Adjustment fineness0.002%*RG,6 digits display

• Protectionsopen-circuit protectionoverload protectionover-heat protection

☆ Calibrate AC Clamp Meter by Single-turn Method
☆ Calibrate DC Clamp meters by Equivalent Ampere-turn Method(optional)
☆ Calibrate Multi-function Clamp Meters